1. Introduction

Document Designer lets dealers design the layout of the documents PSQ produces, such as quotes. You start from a system template, then change the logo, tables, fields, pages and images to match the dealer's needs. The output is a PDF (it cannot currently produce Word documents).

This manual covers the basics:

  1. Copying/Cloning a starter template
  2. Replacing a logo
  3. Editing a regular (static) table
  4. Understanding automatic tables
  5. Building a segments table the recommended way
  6. Inserting data fields
  7. Backgrounds, pages, signature lines and hyperlinks
  8. Testing your template in PSQ
  9. Troubleshooting and known limitations

2. Key Concepts

System template: A starter template provided by Texada. Copying/Cloning it gives you your own editable copy. The basic template closely mimics a typical legacy quote, though no dealer's legacy quote is identical, so expect to adjust it.

Tables: Tables are where data is shown. There are two kinds of Tables:

  1. Static (regular) Table. A table you build yourself from Components. You can control the columns, headings, widths and the data in each cell. Use this whenever you want full control.
  2. Automatic Table. A special table used ONLY for Parts, Labor and Miscellaneous. These Automatic Tables are created by Texada. When "Automatic table" is checked, whatever you see in the editor is a placeholder and is completely replaced at print time by what the “back end” sends. The columns shown depend on the layout options selected in the quote in PSQ on the Documents Tab → Layout.

Data field: A named piece of quote data (for example a contact name, segment number, part number, price, etc.) that you attach to a table, cell or text element so it fills in automatically.

Container: A box that holds other elements. Its main purpose is to give a table access to a list nested inside segments (see Section 7).

Preview data: Sample values shown in the editor so you can see roughly how a field will look. It is a guide only, so always test in PSQ.

3. Before You Start

  • Keep the Document Designer Data Guide open in another window. It lists the data fields available and example values.
  • Work in your demo or sandbox environment, not in a production account.
  • Be signed in to only one environment at a time.

4. Procedure: Clone a System Template

  1. Open Document Designer at Global Landing Hub → Global Console → Document Designer and go to the document template area for your environment (for example the demo sandbox).
  2. Locate the system template you want to start from (for example the PSQ basic template).
  3. Click Clone to make your own copy.
  4. If your clone does not appear at the top of the list, check the second page. New items may be added to the end, and the list is not in alphabetical order.
  5. Delete any old or unused clones so you do not confuse them with your current one.
  6. To make a template available in PSQ, mark it Available, then click Refresh in PSQ so it appears in the template dropdown.
  7. If the system template is updated later, clone it again. Existing clones are not synced.

Tip: A template cloned from the system template is a starting point, not a perfect match for any dealer's legacy quote.

 

5. Procedure: Replace the Logo

  1. Open the template.
  2. Click the existing logo.
  3. In the right-hand properties panel, click Select local file and choose your logo file.
  4. If the logo looks stretched, check the image dimensions shown in the right-hand panel (for example 176 × 24). Enter a width and height with the same ratio. Matching multiples work, for example 352 and 48.
  5. Adjust size and position as needed.

6. Procedure: Edit a Regular (Static) Table

These steps apply only when Automatic table is NOT checked in the right-hand panel. Check this first.

6.1 Edit, add or delete columns

  1. Click the table to select it and confirm that Automatic table is unchecked.
  2. Right-click a column to see the options (insert column to the right, delete column, and so on).
  3. To remove a column, right-click it and choose delete.
  4. To add a column, right-click and choose insert column to the right.
  5. Double-click the new heading cell and type the column heading (for example Contact Name).

6.2 Tie a cell to a data field

  1. Find the field name in the Document Designer Data Guide (for example the header contact name).
  2. Double-click the cell below the heading.
  3. In the right-hand panel, click Insert data field.
  4. Search for the field (for example contact). Results show matching fields with sample values. If search finds nothing, delete a few letters and retype them to refresh.
  5. Choose the right entry. In the session, two contacts existed in the header: one was the quote owner and the other the customer contact. Pick the one you want.
  6. Click Insert, then click elsewhere to see the preview value.
  7. Set the correct type for the column on the right (see Section 6.3).

6.3 Changing the column type and format

  1. Double click the cell in the table and look at the Type setting on the right.
  2. A new column copies the formatting of its neighbor. In the session, a new column placed beside a date column was formatted as a date, so the contact name did not display correctly. Change the type to Text.
  3. Use Text for anything that can contains letters. Segment numbers, for example, can be alphanumeric.
  4. Use a numeric type only for true numbers. For segment numbers, if two decimal places appear, set decimals to 0, or simply use Text.
  5. Click outside the cell to apply.

6.4 Resize columns as needed

  • On a static table, drag the column edges to stretch or shrink them.
  • Column widths on the printed quote remain as you set them. Long text wraps and lengthens the table rather than widening it.

7. Understanding Automatic Tables

Only Parts, Labor and Miscellaneous use automatic tables.

How they behave

  • The columns come from the DOCUMENT LAYOUT settings selected in PSQ found on the DOCUMENTS tab. If the user selects six columns, six are sent. If they select three, three are sent.
  • Everything in the editor (headings, columns, formatting) is replaced when the document is generated.
  • Columns appear in the order Texada defined, and the dealer cannot change it. When you generate from PSQ the order is preserved. Generating from sample data in the editor may show alphabetical order instead. This is only an editor artifact.
  • Formatting is fixed: left-aligned data and equal-width columns. Header alignment can be changed, but data alignment cannot.
  • You can control only the table's overall size and position on the page.

How to show or hide columns of the THREE automatic tables

  1. In PSQ, open the document layout selections.
  2. Select or deselect the columns, for example Extended Price, Job or the codes in brackets.
  3. Generate the document. Unchecked items no longer appear.

NOTE FROM ABOVE. You cannot create an automatic table. Those can only be created by Texada. Clicking the “Automatic Table” button will not do anything.

8. Procedure: Show Parts for Every Segment – Static Table nested inside a Container

Use this when you need a list that sits inside each segment, such as the parts for each segment. NOTE: A segment contains (nested) parts, labor and misc. So if you want to see items/segment, nest the Table within the Container.

Why: If you drag a table and assign Parts directly, it prints parts from only the first segment only. A container tells the system to list all segments, then list the parts within each one.

  1. Open Components and drag a Container onto the page. Make it as large or small as needed.
  2. Select the container and set its Data field to Segments.
  3. Drag a Table from Components into the container.
  4. Select the table and set its Data field to Parts.
  5. Double-click a cell in the second row, click Insert data field, and choose the part field (for example quantity or description).
  6. Type column headings. Right-click to insert or delete columns, since the table defaults to three columns.
  7. To show the segment number above the parts, add a single-column table, insert the segment number field (use segment number or similar; field names have no spaces), and set the type to Text.
  8. Test in PSQ.

Rule of thumb: Use a container only to reach a list inside a segment, or to format several elements at once. Otherwise skip it.

9. Procedure: Insert Header Data (Customer, Equipment, Work Order)

Header data is a single record, not a list, so it cannot be assigned to a whole table.

  1. Drag a Table onto the page.
  2. Click an individual cell (not the table border).
  3. Click Insert data field and search for the header field you want.
  4. Repeat for each cell.
  5. If you are inside a segments table, you cannot reach header fields from there. Add a new element for header data instead.

To add a column heading in any table, left-click the heading cell and type the text.

10. Procedure: Other Template Tasks

10.1 Add a background image

  1. Right-click the page and choose Background image.
  2. On the right, click Select local file and choose the image.
  3. Click Apply. Without this step, the image does not show.
  4. To remove it, right-click the background, choose Background image, then click Remove.

A subtle image, such as a machine picture, works better than a busy one.

10.2 Add a page

  1. Right-click the page and choose Insert page.
  2. Choose Before or After.
  3. To duplicate a page, use copy and paste on the page.

10.3 Add a signature line

  1. Drag a Line component onto the page and stretch it.
  2. Drag a Text component beneath the line and double-click to type Signature.
  3. Adjust the font size, bold or italic, then click Apply.
  4. Select both elements and move them together.

10.4 Insert a hyperlink

  1. Insert a Text box component.
  2. Double click the text box.
  3. Insert Hyperlinks by using an HTML-style tag.
  4. The easiest method is to copy the existing link text box at the bottom of the sample quote and edit it.
  5. In the tag, the left side is the destination link and the right side is the text displayed.
  6. Duplicate or edit as needed.

11. Procedure: Test Your Template

  1. In PSQ, open a quote with enough data (several segments, parts, labor).
  2. Select your template in the drop down, then generate the document.
  3. Check dates, prices (comma plus two decimals), item numbers and column order.
  4. Adjust and repeat.

12. Quick Reference

I want to...

Do this

Replace a logo

Right-click logo → Remove; Components → Image; Select local file; match dimensions

Hide a column on Parts/Labor/Misc

Deselect it in PSQ document layout

Add or remove a column in a regular table

Right-click the column

Show parts for all segments

Container (Segments) + Table (Parts)

List segment details

Table with Data field = Segments

Show header info

Individual cells with Insert data field

Fix a field showing wrong format

Set column Type (Text, number, date)

Add a background

Right-click page → Background image → file → Apply

Add a page

Right-click page → Insert page

Add a link

Edit or copy the existing text box link

Get a field that is missing

Request it from Texada

13. Troubleshooting and Known Limitations

Issue

What to do

Cannot edit columns on Parts, Labor or Misc

These are automatic tables; control columns in PSQ layout

Preview shows header text in parts rows

Expected behavior for automatic tables; test in PSQ

New column shows a date or wrong format

Change Type to Text

Logo is distorted

Enter width and height as the original ratio from the base template

Image does not show after upload

Click Apply

Parts show for one segment only

Use a Container set to Segments

Cannot assign data to an entire header table

Header data is not a list; assign per cell

Needed field (for example standard hours) not in list

Ask Texada to add it

Editor logs you out

Make sure you are signed in to one environment only

Cannot output as Word or Excel

Not supported; output is PDF only